Integrated ODM & OEM Solutions Provider for Industrial Frequency Inverters

Product Category

AC Output Reactor (OCR)

SKU:
Availability:
Quantity:
The input reactor is mounted at the output of the frequency inverter. It is used for limiting the capactive charging current of the connection cable between the frequency inverter and the motor,and passivating the voltage buildup rate of PWM form the frequency inveter and the motor.

Product Feature

Product Introduction

The input reactor is mounted at the output of the frequency inverter. It is used for limiting the capactive charging current of the connection cable between the frequency inverter and the motor,and passivating the voltage buildup rate of PWM form the frequency inveter and the motor.

Product Application

  1. Limit dv / dt to 500V/us
  2. Limit the overvoltage of motor terminal to: 1000V to 400V ~ (rms)
  3. The interference occurred form the contalled between the motor and the filter
  4. Reduce the earth leakage current of motor

Applicable Standards

  1. IEC289:1987 Reactor

  2. GB10229-88 Reactor(eqvIEC 289:1987)

  3. JB9644-1999 Reactor used for semiconductor electrical driving


Product Selection

 Technical Specifications

1. Work voltage: 220VAC-3300VAC
2. Work frequency: 50/60Hz.
3. Work current: 3A-1600A
4. Carrier frequency : 2-8KHz
5. Insulation class: class F, H
6. Operation Environment: -10 ℃+45 ℃,rated value wont′t lower,when higer than 45℃,and every  1℃,the current will step down 2%
  7. Protection class: IP00-IP22
8. Voltage drop: <4% higher than the range will cause the loss of torque
9. Max Current: 1.5 × Rated current,continuous 60S
10. Noise: ≤ 65dB
11. Temperature Rise: ≤ 85K
12. Dielectric strength: Core Coil 3000VAC/50Hz/5mA/10s no electric arcing puncture (factory test)
13. Insulation Resistor: 1000VDC insulation resistance value ≥ 100M?

 14. Under seal level 2000m
 15. Running ambient temperature -25 ℃ ~ +45 ℃, comparative moisture not over 90%.
 16. No hazardous gas,no inflammables and explosives
 17. With well-ventilated condition,ventilation devices shall be mounted if installatioh in panels

Technical Parameter

Product Size

02

380V AC Output Reactor


Reactor Type Picture
NO

Power

(KW)

Rated
Current

(A)

Inductance
Value

(mH)

Voltage
Drop

(%)

Insulation
rank

Dimension

 L±5  

D W   W1   H A*B
OCR-0005-1M40-0.4SC Picture A 1.5 5 1.4
1 F、H 110 90 95 70 130 6*11
OCR-0007-1M00-0.4SC Picture A 2.2 7 1 1 F、H 110 90 95 70 130 6*11
OCR-0010-0M70-0.4SC Picture A 3.7 10 0.7
1 F、H 110 90 95 70 130 6*11
OCR-0015-0M47-0.4SC Picture A 5.5 15 0.47 1 F、H 110 90 95 70 130 6*11
OCR-0200-0M35-0.4SC Picture A 7.5 20 0.35 1 F、H 110 90 95 70 130 6*11
OCR-0030-0M23-0.4SC Picture B 11 30 0.23 1 F、H 155 95 90 73 150 6*15
OCR-0040-0M18-0.4SC Picture B 15 40 0.18 1 F、H 155 95 130 76 135 6*15
OCR-0050-0M14-0.4SC Picture B 18.5 50 0.14 1 F、H 155 95 140
76 135 6*15
OCR-0060-0M12-0.4SC Picture B 22 60 0.12 1 F、H 195 120
135 72 165
8.5*20
OCR-0080-087U-0.4SC Picture B 30 80 0.087 1 F、H 195 120 135 72 165
8.5*20
OCR-0090-078U-0.4SC Picture B 37 90 0.078 1 F、H 195 120 135 72 165
8.5*20
OCR-0120-058U-0.4SA Picture C 45 120
0.058 1 F、H 230 150 170 83 220 11*18
OCR-0150-047U-0.4SA Picture C 55 150 0.0477 1 F、H 230 150 170 88 220
11*18
OCR-0200-035U-0.4SA Picture C 75 200 0.035
1 F、H 230 150 180 98 220 11*18
OCR-0250-028U-0.4SA Picture C 110 250 0.028 1 F、H 250 182 175 98 230 11*18
OCR-00290-024U-0.4SA Picture C 132 290 0.024 1 F、H 290 214 200 107 250 11*18
OCR-0330-021U-0.4SA Picture C 160 330 0.021 1 F、H 290 214 200 107 250 11*18
OCR-0390-018U-0.4SA Picture C 185 390 0.018 1 F、H 290 214 200 107 250 11*18
OCR-0490-014U-0.4SA Picture C 220 490 0.014 1 F、H 320 243 230 125 320 12*20
OCR-0600-012U-0.4SA Picture C 280 600 0.012 1 F、H 320 243 250 140 320 12*20
OCR-0660-011U-0.4SA Picture C 300 660 0.011 1 F、H 320 243 250 140 320 12*20
OCR-0800-08U7-0.4SA Picture D 380 800 0.0087 1 F、H 365 260 280 135 380 15*25
OCR-1000-07U0-0.4SA Picture D 450 1000 0.007 1 F、H 365 260 280 135 380 15*25
OCR-1200-05U8-0.4SA Picture D 550 1200 0.0058 1 F、H 395 260 325 150 390 15*25
OCR-1600-04U3-0.4SA Picture D 630 1600 0.0043 1 F、H 395 260 325 150 435 15*25

690V AC Output Reactor


Reactor Type Picture
NO

Power

(KW)

Rated
Current

(A)

Inductance
Value

(mH)

Voltage

Drop

(%)

Insulation
rank

Dimension

L±5  

D W W1 H   A*B
OCR-0005-2M80-0.7SC Picture A 3.7
5
2.8
1 F、H 155 95
130 61 150
6*15
OCR-0007-2M00-0.7SC Picture A 5.5 7 2
11 F、H 155 95 130 61 150 6*15
OCR-0010-1M40-0.7SC Picture A 7.5 10 1.4 1 F、H 155 80 200 95 63 6*15
OCR-0015-0M93-0.7SC Picture A 11 15 0.93
1 F、H 155 80 200 95 63 6*15
OCR-0020-0M70-0.7SC Picture B 15/18.5
20 0.7 1 F、H 155 80 200 95 63 6*15
OCR-0030-0M47-0.7SC Picture B 22 30 0.47
1 F、H 195 130 165 120 72 8.5*20
OCR-0040-0M35-0.7SC Picture B 30 40 0.35 1 F、H 195 130 165 120 72 8.5*20
OCR-0050-0M28-0.7SA Picture B 37/45
50 0.28
1 F、H 195 150 165 120 92 8.5*20
OCR-0060-0M23-0.7SA Picture B 55
60 0.23 1 F、H 195 150 165 120 92 8.5*20
OCR-0080-0M18-0.7SA Picture C 75 80 0.18 1 F、H 195 170 165 120 112 8.5*20
OCR-0120-0M12-0.7SA Picture C 110
120 0.12 1 F、H 250 190 230 182 103 11*18
OCR-0150-094U-0.7SA Picture C 132 150 0.094
1 F、H 250 200 230 182

113

11*18
OCR-0200-070U-0.7SA Picture C 160/185
200 0.07 1 F、H 290 220 250 214 117 11*18
OCR-0250-055U-0.7SA Picture C 220
250 0.055 1 F、H 290 220 250 214 117 11*18
OCR-0290-048U-0.7SA Picture C 240 290
0.048 1 F、H 320 250 320 243 135 12*20
OCR-0330-042U-0.7SA Picture C 280/300 330 0.042 1 F、H 320 250 320 243 135 12*20
OCR-0390-036U-0.7SA Picture C 380 390 0.036 1 F、H 320 250 320 243 135 12*20
OCR-0490-028U-0.7SA Picture C 450
490 0.028 1 F、H 320 270 320 243 160 12*20
OCR-0600-023U-0.7SA Picture D 550 600
0.023 1 F、H 365 285 340 260 165 15*25
OCR-0660-021U-0.7SA Picture D 630 660 0.021 1 F、H 365 285 340 260 165 15*25


Customization & ODM Capabilities

More Than a Standard Product. It's Your Custom Starting Point
This platform is designed for adaptation and supports:
Software Tailoring
Modify parameters and develop specialized functions.
Hardware Adaptation
Adjust mechanical design and swap key components.
Complete Branding
Apply your logo and packaging seamlessly.
Build Your Brand. 
Shape the Future of Industry.
Janson Controls Technologies(Shenzhen)Co.,Limited
 Add: 3rd Floor, Building E, Fuxing Industrial Park,No.110, Zhangqi Road,       
            Guixiang Community,Guanlan Street, Longhua District, Shenzhen, China.
 Tel: +86-0755-29611160
 Whatsup:+8613590499063
 Email: info@jansoncontrols.com
 Working hours: Monday to Friday: 9:00 AM - 6:00 PM (GMT+8)