+86-13590499063             info@jansoncontrols.com
You are here: Home / Application / Industrial Washing Machine

Industrial Washing Machine

1, Load feature

(1) During washing processing, the running frequency is around 10Hz.

(2) Heavy load at low frequency.

(3) Forward / reverse running are switched frequently.

(4) Big surge current.

(5) During spinning-dry processing, the running frequency is as high as 130Hz or higher than 130Hz.

(6) It always works at high humidity and high temperature conditions.


2, Requests for frequency inverters (VFD)

(1) Output high torque at low frequency.

(2) Big capacity of over current and over load.

(3) It should run stably at high speed.


3, Instruction for commissioning

(1) Pictures of industrial washing machine


(2) Parameters setting list

No.

Function codes

Default

Setting value

Explanation

1

F00.00

2

2

V/f control

2

F00.01

0

1

External start / stop signal

3

F00.06

10

6

Multi-step speed control

4

F00.03

50

150

Maximum frequency

5

F00.03

50

150

Frequency upper limit

6

F00.12

Model depend

30

Acceleration time (adjustable)

7

F00.13

Model depend

30

Deceleration time (adjustable)

8

F01.09

0

5

DC braking start frequency while stopping

9

F01.11

0

40%

DC braking current while stopping

10

F01.12

0

1

DC braking time while stopping

11

F04.01


0

Torque boost automatically (it can set another value by real request)

12

F06.00

1

1

Forward run

13

F06.01

2

2

Reverse run

14

F06.02

0

6

Multi-step speed terminal 1

15

F06.03

0

7

Multi-step speed terminal 2

16

F06.04

0

8

Multi-step speed terminal 3

17

F12.02

0

8%

Washing speed

18

F12.03

0

10%

Equispaced speed

19

F12.06

0

70%

Medium spinning speed

20

F12.10

0

100%

High spinning speed



(3) Typical wiring diagram

4, Notices

(1) The corresponding relationship between multi-step speed and wash process should be correct; each step speed should beadjusted base on real requests.

(2) Because of the industrial washing machine sometimes will work at overload condition, the power of VFD should be selectedone size higher usually.

(3) The machine must be grounded reliably, pay attention to moisture-proof measures, the system must be maintained regularly.



The company's main business covers high, medium and low voltage variable frequency drives, servo drives, solar inverters and related products.