1, Load Feature:
(1) With big fluctuation. (2) Lots of dusts in the operation sites.
2, Requests For VFD:
(1) Soft start the motor, reduce the surge current, protect the motor and conveyer.
(2) Big output torque at low frequency, it should run smoothly during working.
(3) Motor speed can be adjusted by external potentiometer.
(4) Running current can be monitored timely.
(5) While the failures happen, the AC drive can output alarm or stop.
3, System Diagram:
4, Wire Diagram:
5, Parameter Setting Step:
Step | Function Code | Factory Default | Set Value | Description |
1 | P102 | 0 | 1 | The Operation Setting is Selected as I/O Terminal |
2 | P101 | 3 | 1 | Frequency setting selection analog voltage mode |
3 | P107 | Change | Set as need | Acceleration time |
4 | P108 | Change | Set as need | Deceleration time |