Integrated ODM & OEM Solutions Provider for Industrial Frequency Inverters
You are here: Home / Application / CNC Machine

CNC Machine

1, Load feature

CNC machine is a mechanical-electrical integrated system include mechanic, electric, hydraulic, pneumatic, microelectronics and information technology, it has the features of high accuracy, highly automated and highly flexible.

2, Requests for inverters (VFD)
(1)  It can work normally at 300RPM speed, has good stability, high control accuracy, fast response speed and high output torque at low speed.
(2)  It should have external forward / reverse control signal and analog input signal.

3, Instruction for commissioning
(1)  Onsite picture


(2)  Parameters list (Take 380V, 4KW as example)

No.

Function codes

Default

Setting value

Explanation

1

F00.00

2

0

Sensorless vector control (SVC)

2

F02.01

Model depend

-

Set them based on the motor nameplate value

3

F02.02

Model depend

-

4

F02.03

Model depend

-

5

F02.04

Model depend

-

6

F02.05

Model depend

-

7

F02.37

0

2

Rotation autotuning (disconnect the load)

8

F00.01

0

1

External start / stop signal

9

F00.06

10

2

External VI signal (analog signal) to control the   output frequency

10

F00.03

50Hz

100Hz

Set the max. frequency based on real request

11

F00.04

50Hz

100Hz

Set the upper limit frequency based on real request

12

F00.12

Model depend

0.5s

Set the acceleration time based on real request

13

F00.13

Model depend

0.5s

Set the deceleration time based on real request

14

F01.09

0

0.5

DC braking start frequency while stopping

15

F01.10

0

0s

DC braking delay time while stopping

16

F01.11

0%

100%

DC braking current while stopping

17

F01.12

0s

1s

DC braking time while stopping


(3)  Typical wiring diagram


4, Notices
(1)  Under the SVC control mode, it must perform the auto tunning firstly, then set the other parameters.
(2)   Please pay attention to ACC/DEC time setting and also the braking resistor’s selection.
(3)  The installation environment should be safe, to avoid the iron dust and other items to enter into inverter.


Build Your Brand. 
Shape the Future of Industry.
Janson Controls Technologies(Shenzhen)Co.,Limited
 Add: 3rd Floor, Building E, Fuxing Industrial Park,No.110, Zhangqi Road,       
            Guixiang Community,Guanlan Street, Longhua District, Shenzhen, China.
 Tel: +86-0755-29611160
 Email: info@jansoncontrols.com
 Working hours: Monday to Friday: 9:00 AM - 6:00 PM (GMT+8)

Quick Links

Service Support

Product Category

Copyright © 2023 Janson Controls Technologies (Shenzhen) Co., Ltd. Sitemap