+86-13590499063             info@jansoncontrols.com
You are here: Home / Application / Carving Machine

Carving Machine

1, Load feature

(1) It is used to drive high speed motor, the maximum speed is about 24000RPM, correspond to 400Hz, the minimum speed isabout 2000RPM.

(2) It needs high torque at low speed.


2, Requests for frequency inverters (VFD)

(1) Wide range of operation frequency.

(2) It needs multi-points V/f carve, which can control the output torque at different speed.

(3) An external input ON/OFF signal will be used to start and stop the frequency inverter, an external input analog signal will be usedto control the output frequency and it needs fault reset input signal and fault output signal.


3, Instruction for commissioning

(1) Pictures of carving machine


(2) Parameters list


Take 400Hz, 380V and 24000RPM carving machine as example.


No.

Function codes

Default

Setting value

Explanation

1

F00.01

0

1

External start / stop signal

2

F00.06

10

2

External VI signal (analog signal) to control the output frequency

3

F06.00

1

1

Start

4

F06.01

2

3

Three-line mode EN

5

F06.13

0

2

Three-line mode 1

6

F06.02

0

7

Fault reset

7

F07.02

3

3

Fault output

8

F09.13

0

1

Reverse forbidden

9

F00.03

50

400

Maximum frequency 400Hz

10

F00.04

50

400

Upper limit frequency 400Hz

11

F02.02

50

400

Motor rated frequency 400Hz

12

F02.03

Model depend

24000

Motor rated RPM

13

F04.00

0

1

Multi-points V/f carve

14

F04.02

50

400

Torque boost cutoff frequency (400Hz)

15

F04.03

0

0

V/f frequency point 1 (0Hz)

16

F04.04

0%

2.0~4.0%

V/f voltage point 1

17

F04.05

0

100

V/f frequency point 2 (100Hz)

18

F04.06

0%

26~30%

V/f voltage point 2

19

F04.07

0

300

V/f frequency point 3 (300Hz)

20

F04.08

0%

75~80%

V/f voltage point 3


(3)Typical wiring diagram


4, Notices

(1) To ensure the over current fault will not happen, the multi-points V/f setting in F04 group should be set base on real requests, thevoltage points and frequency points should follow the rule of V/f1< V/f2< V/f3, and the voltage at low frequency cannot be set too big.

(2) The motor’s parameters on the nameplate of carving machine should be set correctly in do group.