Integrated ODM & OEM Solutions Provider for Industrial Frequency Inverters
You are here: Home / Application / Circular Knitting Machine

Circular Knitting Machine

1, Load feature

Circular Knitting Machine is widely used in the textile industry, it’s usually started by external signal, speed iscontrolled by external analog signal.

The running speed is high, start torque is high, and also the system always needs fast stop.


2, Requests for AC Drive (VFD)

(1) Big output torque at low frequency.

(2) Fast response during start.

(3) Running smoothly during running.

(4) Stop smoothly and accurately, without reverse.


3, Onsite picture


4, Typical wiring diagram



5, Parameters setting list


No.

Function codes

Default

Setting value

Explanation

1

F00.01

0

1

External start / stop signal

2

F00.06

10

2

The speed is controlled by external 0~10V signal

3

F00.03

50

80

Maximum frequency

4

F00.04

50

80

Frequency upper limit

5

F00.12

Model depend

5s

Acceleration time (adjustable)

6

F00.13

Model depend

0.5s

Deceleration tiem (adjustable)

7

F01.09

0

1.5

DC braking start frequency while stopping

8

F01.11

0

60

DC braking current while stopping

9

F01.12

0

0.8s

DC braking time while stopping

10

F07.02

3

3

Fault output

11

F09.13

0

1

Reverse forbidden


6, Notices

(1) Maintenance regularly, pay attention to ventilation, heat sink, and dust prevention.

(2) Before running the machine, remove the load and adjust the motor running direction to be correct.

(3) Pay special attention on the reversal while stopping, a slight reverse will cause damage to the dial, customer canchange the S-curve mode or fine tuning the DC braking parameters to remove the reversal.



Build Your Brand. 
Shape the Future of Industry.
Janson Controls Technologies(Shenzhen)Co.,Limited
 Add: 3rd Floor, Building E, Fuxing Industrial Park,No.110, Zhangqi Road,       
            Guixiang Community,Guanlan Street, Longhua District, Shenzhen, China.
 Tel: +86-0755-29611160
 Email: info@jansoncontrols.com
 Working hours: Monday to Friday: 9:00 AM - 6:00 PM (GMT+8)

Quick Links

Service Support

Product Category

Copyright © 2023 Janson Controls Technologies (Shenzhen) Co., Ltd. Sitemap