| SKU: | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Availability: | |||||||||
| Quantity: | |||||||||
| SSD60: The High-Efficiency Shield for Your High-Power Motors. The SSD60 Series by Janson Controls is a professional-grade, solid-state soft starter designed to tame the massive inrush currents of large asynchronous motors. By integrating a high-quality Bypass Contactor internally, the SSD60 provides a complete motor-starting solution that is more compact, more efficient, and easier to install than traditional systems. Integrated Bypass Excellence: No need to purchase or wire an external AC contactor. Once the motor reaches full speed, the SSD60 automatically switches to the internal bypass, minimizing heat generation and energy loss. Tackle the Toughest Loads: Beyond standard starts, the SSD60 features a specialized "Swing Start" mode, specifically engineered to break the static friction of eccentric loads like Ball Mills and heavy crushers. Superior Mechanical Protection: By providing a smooth, linear acceleration, the SSD60 eliminates "water hammer" in pumps and reduces belt slippage in conveyors, extending the life of your mechanical assets by years. Smart Monitoring: Equipped with a large-screen LCD, it provides real-time visibility into three-phase currents and voltages, making it the most user-friendly starter in its class. | |||||||||
SSD60
Janson Controls
1.Integrated Bypass & Efficiency
All-in-One Architecture: The built-in bypass contactor significantly reduces the size of your control cabinet. It automatically engages after the start sequence, ensuring the thyristors stay cool and live longer.
Robust Metal Housing: Designed for wall mounting in harsh industrial environments, offering superior physical protection and EMC shielding.
2.Intelligent Motion Profiles
6 Start Modes for Every Scenario: Includes Voltage Ramp, Current Limit, and the unique "Swing Start" (for high-inertia loads). It ensures your motor starts every time without tripping the circuit breaker.
Smooth Deceleration: Features soft-stop and DC injection braking to prevent damaging surges in fluid systems (water hammer) or abrupt stops in conveyor belts.
3.Professional Protection Suite
Inverse-Time Overload Logic: Sophisticated algorithms track the motor’s thermal state to prevent burnout while allowing for necessary starting overhead.
Full Diagnostic Logging: Stores the last 12 fault records with time stamps, allowing your team to identify and solve issues in minutes, not days.
4.Industrial Connectivity
Smart Integration: Supports Modbus-RTU (RS485) as standard, allowing for seamless connection to PLC and SCADA systems for remote monitoring.
Flexible I/O: 2 programmable relays and a 4-20mA analog output provide the signals needed for complex automation sequences.
1.Integrated Bypass & Efficiency
All-in-One Architecture: The built-in bypass contactor significantly reduces the size of your control cabinet. It automatically engages after the start sequence, ensuring the thyristors stay cool and live longer.
Robust Metal Housing: Designed for wall mounting in harsh industrial environments, offering superior physical protection and EMC shielding.
2.Intelligent Motion Profiles
6 Start Modes for Every Scenario: Includes Voltage Ramp, Current Limit, and the unique "Swing Start" (for high-inertia loads). It ensures your motor starts every time without tripping the circuit breaker.
Smooth Deceleration: Features soft-stop and DC injection braking to prevent damaging surges in fluid systems (water hammer) or abrupt stops in conveyor belts.
3.Professional Protection Suite
Inverse-Time Overload Logic: Sophisticated algorithms track the motor’s thermal state to prevent burnout while allowing for necessary starting overhead.
Full Diagnostic Logging: Stores the last 12 fault records with time stamps, allowing your team to identify and solve issues in minutes, not days.
4.Industrial Connectivity
Smart Integration: Supports Modbus-RTU (RS485) as standard, allowing for seamless connection to PLC and SCADA systems for remote monitoring.
Flexible I/O: 2 programmable relays and a 4-20mA analog output provide the signals needed for complex automation sequences.
Product Selection
| Item No. | Adaptable Motor (kW) | Current (A) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | Diameter (mm) | GW (kg) |
| 3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||
| SSD60-4T-15 | 15 | 30 | 155 | 320 | 195 | 135 | 295 | Ø6 | 5 |
| SSD60-4T-22 | 22 | 45 | |||||||
| SSD60-4T-30 | 30 | 60 | |||||||
| SSD60-4T-37 | 37 | 75 | |||||||
| SSD60-4T-45 | 45 | 90 | |||||||
| SSD60-4T-55 | 55 | 110 | |||||||
| SSD60-4T-75 | 75 | 150 | 245 | 410 | 255 | 200 | 345 | Ø8 | 15 |
| SSD60-4T-90 | 90 | 180 | |||||||
| SSD60-4T-110 | 110 | 230 | |||||||
| SSD60-4T-132 | 132 | 260 | 300 | 605 | 250 | 215 | 536 | Ø8 | 22 |
| SSD60-4T-160 | 160 | 320 | |||||||
| SSD60-4T185 | 185 | 370 | |||||||
| SSD60-4T-200 | 200 | 400 | |||||||
| SSD60-4T-250 | 250 | 500 | 340 | 661 | 260 | 265 | 590 | Ø10 | 30 |
| SSD60-4T-280 | 280 | 560 | |||||||
| SSD60-4T-320 | 320 | 630 | |||||||
Product Selection
| Item No. | Adaptable Motor (kW) | Current (A) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | Diameter (mm) | GW (kg) |
| 3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||
| SSD60-4T-15 | 15 | 30 | 155 | 320 | 195 | 135 | 295 | Ø6 | 5 |
| SSD60-4T-22 | 22 | 45 | |||||||
| SSD60-4T-30 | 30 | 60 | |||||||
| SSD60-4T-37 | 37 | 75 | |||||||
| SSD60-4T-45 | 45 | 90 | |||||||
| SSD60-4T-55 | 55 | 110 | |||||||
| SSD60-4T-75 | 75 | 150 | 245 | 410 | 255 | 200 | 345 | Ø8 | 15 |
| SSD60-4T-90 | 90 | 180 | |||||||
| SSD60-4T-110 | 110 | 230 | |||||||
| SSD60-4T-132 | 132 | 260 | 300 | 605 | 250 | 215 | 536 | Ø8 | 22 |
| SSD60-4T-160 | 160 | 320 | |||||||
| SSD60-4T185 | 185 | 370 | |||||||
| SSD60-4T-200 | 200 | 400 | |||||||
| SSD60-4T-250 | 250 | 500 | 340 | 661 | 260 | 265 | 590 | Ø10 | 30 |
| SSD60-4T-280 | 280 | 560 | |||||||
| SSD60-4T-320 | 320 | 630 | |||||||
Technical Parameter
| Control power supply | AC 380V(-10%~15%), 50hz/60hz (provided internally, users do not need to connect externally. | |
| Input power supply | AC 380V-10%~15% 50Hz/60Hz | |
| Applicable motor | General squirrel cage AC asynchronous motor | |
| Starting mode | Current limiting starting; Voltage ramp start; Sudden tripping current limiting start; Jump voltage ramp start; Inching start; Swing start. | |
| Stop mode | Free shutdown; Soft shutdown; DC brake stop. | |
| Relay output | Two way programmable output relay | |
| Starting frequency | Not more than 15 times in an hour | |
| Protection function | Input phase loss, startup overload, operation overload, overcurrent, current imbalance, overvoltage, undervoltage, overheating, output phase loss, etc. | |
| Display | Large screen LCD, Chinese and English display modes. Display current three-phase output current, grid voltage, fault type, systemparameters and operating parameters. | |
| Degree of protection | IP20(55kW and below) / IP00(75kW and above) | |
| Cooling mode | Forced air cooling /natural cooling | |
| Installation method | Wall mounted | |
| Environment condition | Equipment site | Indoor, no direct sunlight, no dust, corrosive gas, fammable gas, oil mist,water vapor, dripping water or salt, etc. |
| Ambient temperature | -25℃ ~+40℃ | |
| Ambient humidity | Below 90%(no condensation) | |
| Vibration intensitty | Below 0.5g(acceleration) | |
| Altitude | Below 1000m(derating is required if the altitude exceeds) | |
| Adapter motor | 15~320KW | |
Technical Parameter
| Control power supply | AC 380V(-10%~15%), 50hz/60hz (provided internally, users do not need to connect externally. | |
| Input power supply | AC 380V-10%~15% 50Hz/60Hz | |
| Applicable motor | General squirrel cage AC asynchronous motor | |
| Starting mode | Current limiting starting; Voltage ramp start; Sudden tripping current limiting start; Jump voltage ramp start; Inching start; Swing start. | |
| Stop mode | Free shutdown; Soft shutdown; DC brake stop. | |
| Relay output | Two way programmable output relay | |
| Starting frequency | Not more than 15 times in an hour | |
| Protection function | Input phase loss, startup overload, operation overload, overcurrent, current imbalance, overvoltage, undervoltage, overheating, output phase loss, etc. | |
| Display | Large screen LCD, Chinese and English display modes. Display current three-phase output current, grid voltage, fault type, systemparameters and operating parameters. | |
| Degree of protection | IP20(55kW and below) / IP00(75kW and above) | |
| Cooling mode | Forced air cooling /natural cooling | |
| Installation method | Wall mounted | |
| Environment condition | Equipment site | Indoor, no direct sunlight, no dust, corrosive gas, fammable gas, oil mist,water vapor, dripping water or salt, etc. |
| Ambient temperature | -25℃ ~+40℃ | |
| Ambient humidity | Below 90%(no condensation) | |
| Vibration intensitty | Below 0.5g(acceleration) | |
| Altitude | Below 1000m(derating is required if the altitude exceeds) | |
| Adapter motor | 15~320KW | |