| SKU: | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Availability: | |||||||||
| Quantity: | |||||||||
| FC320L: Engineering the Perfect Ride. The FC320L is not just a frequency inverter; it is the dedicated intelligence behind modern elevator systems. Specifically designed for both new installations and elevator modernization, it focuses on the three pillars of vertical transportation: Comfort, Safety, and Efficiency. Mirror-Smooth Comfort: Say goodbye to start-up jerks. With optimized S-curve algorithms and Pre-torque Compensation, the FC320L ensures an imperceptible transition from standstill to motion. Proactive Safety: Built-in emergency evacuation support (48V battery) and over 10 real-time safety monitors ensure passengers are never stranded during power failures. Universal Compatibility: A single platform for both PMSM and Induction motors, simplifying your inventory and engineering process. Integrated Reliability: Built-in DC reactors and braking units reduce cabinet space and system costs while enhancing power quality. | |||||||||
FC320L
Janson Controls
1.Algorithm-Defined Ride Quality
Precision S-Curve: Fully customizable acceleration/deceleration profiles for a "mirror-smooth" ride.
Auto-Tuning Excellence: Static and dynamic motor auto-tuning for perfect matching with any lift motor brand.
Anti-Rollback Logic: High-torque at zero speed ensures the car stays firm when the brake releases.
2.Safety-First Intelligence
ARD Support (Automatic Rescue Device): Seamlessly integrates with 48V/96V battery systems for emergency evacuation.
Comprehensive Protection: Real-time monitoring of contactor adhesion, overspeed, and motor over-temperature.
Reliable in Harsh Grids: Designed to handle voltage fluctuations common in developing infrastructure.
3.Engineering-Friendly Integration
Compact Cabinet Footprint: Internal components (DC reactor/Braking unit) reduce external wiring and box size.
Smart Commissioning: RJ45 interface for easy keypad connection, allowing parameter setting from anywhere in the machine room.
Standardized Interfaces: Rich encoder (Sin/Cos, UVW, ABZ) and communication options for global elevator control systems.
1.Algorithm-Defined Ride Quality
Precision S-Curve: Fully customizable acceleration/deceleration profiles for a "mirror-smooth" ride.
Auto-Tuning Excellence: Static and dynamic motor auto-tuning for perfect matching with any lift motor brand.
Anti-Rollback Logic: High-torque at zero speed ensures the car stays firm when the brake releases.
2.Safety-First Intelligence
ARD Support (Automatic Rescue Device): Seamlessly integrates with 48V/96V battery systems for emergency evacuation.
Comprehensive Protection: Real-time monitoring of contactor adhesion, overspeed, and motor over-temperature.
Reliable in Harsh Grids: Designed to handle voltage fluctuations common in developing infrastructure.
3.Engineering-Friendly Integration
Compact Cabinet Footprint: Internal components (DC reactor/Braking unit) reduce external wiring and box size.
Smart Commissioning: RJ45 interface for easy keypad connection, allowing parameter setting from anywhere in the machine room.
Standardized Interfaces: Rich encoder (Sin/Cos, UVW, ABZ) and communication options for global elevator control systems.
| Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | GW (kg) |
| 1/3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | ||||||||||
| FC320L-4T-4.0GB | 4 | 10.5 | 9 | 5.9 | 160 | 248 | 183 | 148 | 236 | 2.5 |
| FC320L-4T-5.5GB | 5.5 | 14.8 | 13 | 8.9 | ||||||
| FC320L-4T-7.5GB-M | 7.5 | 20.5 | 18 | 11 | ||||||
| FC320L-4T-7.5GB | 7.5 | 19 | 17 | 11 | 208 | 322 | 192 | 190 | 305 | 6.5 |
| FC320L-4T-11GB | 11 | 28 | 25 | 16 | 6.8 | |||||
| FC320L-4T-15GB | 15 | 35 | 32 | 21 | 7.3 | |||||
| Item No. | Remark | ||||||||||
| 320L-PG-A4 | AB Incrementall Encoder | ||||||||||
| 320L-PG-C | Sin/Cos Encoder | ||||||||||
| 320L-PG-C2 | |||||||||||
| 320L-PG-C3 | |||||||||||
| 320L-PG-B | UVW Encoder | ||||||||||
| 320L-PG-C5 | Absolute Encoder Endat | ||||||||||
| Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | GW (kg) |
| 1/3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | ||||||||||
| FC320L-4T-4.0GB | 4 | 10.5 | 9 | 5.9 | 160 | 248 | 183 | 148 | 236 | 2.5 |
| FC320L-4T-5.5GB | 5.5 | 14.8 | 13 | 8.9 | ||||||
| FC320L-4T-7.5GB-M | 7.5 | 20.5 | 18 | 11 | ||||||
| FC320L-4T-7.5GB | 7.5 | 19 | 17 | 11 | 208 | 322 | 192 | 190 | 305 | 6.5 |
| FC320L-4T-11GB | 11 | 28 | 25 | 16 | 6.8 | |||||
| FC320L-4T-15GB | 15 | 35 | 32 | 21 | 7.3 | |||||
| Item No. | Remark | ||||||||||
| 320L-PG-A4 | AB Incrementall Encoder | ||||||||||
| 320L-PG-C | Sin/Cos Encoder | ||||||||||
| 320L-PG-C2 | |||||||||||
| 320L-PG-C3 | |||||||||||
| 320L-PG-B | UVW Encoder | ||||||||||
| 320L-PG-C5 | Absolute Encoder Endat | ||||||||||
| Basic Specifications | |
| Carrier frequency | 2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted |
| Input frequency resolution | Digital setting: 0.01Hz |
| Analog setting: maximum frequency × 0.1% | |
| Output frequency accuracy | Digital setting: maximum frequency × ±0.01% |
| Analog setting: maximum frequency × ±0.01% | |
| Control method | Open-loop vector control (SVC)/ closed-loop vector control (FVC)/ VF control |
| Starting torque | 0.5Hz/180%(SVC); 0Hz/200%(FVC) |
| Speed range | 1:100(SVC)/1:1000(FVC) /1:50 (V/F) |
| Steady speed accuracy | ±0.5%(SVC) ±0.05%(FVC) |
| Overload capacity | 150% rated current for 60 seconds; 180% rated current for 1 second. |
| Motor tuning | Tuning with load; Tuning without load |
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations |
| Maintenance control | Can be specified by any number of speeds |
| Multi-speed operation | Realize up to 8-speed operation |
| Automatic voltage regulator(AVR) | When the grid voltage changes, it can automatically keep the output voltage constant |
| Display And Operation | |
| LED display | Can display setting frequency, output frequency, output voltage, output current and other parameters. |
| Protective function | Power-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection 40 kinds of protection. |
| Key lock and function selection | Realize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse. |
| Personalization | |
| Power-on peripheral equipment safety self-test | It can realize safety detection of peripheral equipment such as grounding, short circuit etc. |
| Power failure emergency Operation | Simple and convenient implementation of emergency operation plan |
| Over-speed protection | Built-in elevator overspeed protection function; multiple action options |
| Judge speed deviation | Built-in speed deviation detection function; discover potential hidden dangers of elevators in time. |
| Forced shift function | It has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom. |
| Direct docking function | Combined with direct docking commands for crawl-free operation |
| Motor temperature detection | Timely judge the motor temperature to eliminate potential safety hazards |
| Start compensation | Three starting torque compensation methods: analog, digital, no weighing |
| QUICK button | User-defined shortcut menu |
| Timing control | Convenient timing control function |
| Input And Output Characteristics | |
| Run command channel | Two channels: operation panel given, control terminal given. |
| Frequency source | 4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference. |
| Input terminal | 10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode. |
| 2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input. | |
| Output terminal | 3 digital output terminals |
| 2 relay output terminals | |
| 1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency | |
| Environmental Characteristics | |
| Working temperature | -10~+40℃, up to 50℃, air temperature change is less than 0.5℃/min |
| Storage temperature | -40~+70℃ |
| Application occasion | Indoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
| Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
| Humidity | Less than 95%RH, no condensation |
| Vibration resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
| Protection degree | IP20 |
| Pollution level | Class 2 (dry, non-conductive dust pollution) |
| Basic Specifications | |
| Carrier frequency | 2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted |
| Input frequency resolution | Digital setting: 0.01Hz |
| Analog setting: maximum frequency × 0.1% | |
| Output frequency accuracy | Digital setting: maximum frequency × ±0.01% |
| Analog setting: maximum frequency × ±0.01% | |
| Control method | Open-loop vector control (SVC)/ closed-loop vector control (FVC)/ VF control |
| Starting torque | 0.5Hz/180%(SVC); 0Hz/200%(FVC) |
| Speed range | 1:100(SVC)/1:1000(FVC) /1:50 (V/F) |
| Steady speed accuracy | ±0.5%(SVC) ±0.05%(FVC) |
| Overload capacity | 150% rated current for 60 seconds; 180% rated current for 1 second. |
| Motor tuning | Tuning with load; Tuning without load |
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations |
| Maintenance control | Can be specified by any number of speeds |
| Multi-speed operation | Realize up to 8-speed operation |
| Automatic voltage regulator(AVR) | When the grid voltage changes, it can automatically keep the output voltage constant |
| Display And Operation | |
| LED display | Can display setting frequency, output frequency, output voltage, output current and other parameters. |
| Protective function | Power-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection 40 kinds of protection. |
| Key lock and function selection | Realize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse. |
| Personalization | |
| Power-on peripheral equipment safety self-test | It can realize safety detection of peripheral equipment such as grounding, short circuit etc. |
| Power failure emergency Operation | Simple and convenient implementation of emergency operation plan |
| Over-speed protection | Built-in elevator overspeed protection function; multiple action options |
| Judge speed deviation | Built-in speed deviation detection function; discover potential hidden dangers of elevators in time. |
| Forced shift function | It has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom. |
| Direct docking function | Combined with direct docking commands for crawl-free operation |
| Motor temperature detection | Timely judge the motor temperature to eliminate potential safety hazards |
| Start compensation | Three starting torque compensation methods: analog, digital, no weighing |
| QUICK button | User-defined shortcut menu |
| Timing control | Convenient timing control function |
| Input And Output Characteristics | |
| Run command channel | Two channels: operation panel given, control terminal given. |
| Frequency source | 4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference. |
| Input terminal | 10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode. |
| 2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input. | |
| Output terminal | 3 digital output terminals |
| 2 relay output terminals | |
| 1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency | |
| Environmental Characteristics | |
| Working temperature | -10~+40℃, up to 50℃, air temperature change is less than 0.5℃/min |
| Storage temperature | -40~+70℃ |
| Application occasion | Indoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
| Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
| Humidity | Less than 95%RH, no condensation |
| Vibration resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
| Protection degree | IP20 |
| Pollution level | Class 2 (dry, non-conductive dust pollution) |
content is empty!