Professional VFD manufacturer, supporting customization.

Product Category

FC320L Series | High-Performance Elevator VFD & Lift Drive

SKU:
Availability:
Quantity:
FC320L: Engineering the Perfect Ride.

The FC320L is not just a frequency inverter; it is the dedicated intelligence behind modern elevator systems. Specifically designed for both new installations and elevator modernization, it focuses on the three pillars of vertical transportation: Comfort, Safety, and Efficiency.

Mirror-Smooth Comfort:  Say goodbye to start-up jerks. With optimized S-curve algorithms and Pre-torque Compensation, the FC320L ensures an imperceptible transition from standstill to motion.

Proactive Safety:  Built-in emergency evacuation support (48V battery) and over 10 real-time safety monitors ensure passengers are never stranded during power failures.

Universal Compatibility:  A single platform for both PMSM and Induction motors, simplifying your inventory and engineering process.

Integrated Reliability:  Built-in DC reactors and braking units reduce cabinet space and system costs while enhancing power quality.
  • FC320L

  • Janson Controls

Item No.

Adaptable Motor

 (kW)

Input Current (A)Output Current (A)Rate Capacity (kVA)

W

(mm)

H

(mm)

D

(mm)

W1

(mm)

H1

(mm)

GW

(kg)

1/3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC320L-4T-4.0GB410.595.9160
248
183
148
236
2.5
FC320L-4T-5.5GB5.514.8138.9
FC320L-4T-7.5GB-M7.520.51811
FC320L-4T-7.5GB7.519
17112083221921903056.5
FC320L-4T-11GB112825166.8
FC320L-4T-15GB153532
217.3
Item No.Remark
320L-PG-A4AB Incrementall Encoder
320L-PG-CSin/Cos Encoder
320L-PG-C2
320L-PG-C3
320L-PG-BUVW Encoder
320L-PG-C5Absolute Encoder Endat


1.Algorithm-Defined Ride Quality

  • Precision S-Curve: Fully customizable acceleration/deceleration profiles for a "mirror-smooth" ride.

  • Auto-Tuning Excellence: Static and dynamic motor auto-tuning for perfect matching with any lift motor brand.

  • Anti-Rollback Logic: High-torque at zero speed ensures the car stays firm when the brake releases.

2.Safety-First Intelligence

  • ARD Support (Automatic Rescue Device): Seamlessly integrates with 48V/96V battery systems for emergency evacuation.

  • Comprehensive Protection: Real-time monitoring of contactor adhesion, overspeed, and motor over-temperature.

  • Reliable in Harsh Grids: Designed to handle voltage fluctuations common in developing infrastructure.

3.Engineering-Friendly Integration

  • Compact Cabinet Footprint: Internal components (DC reactor/Braking unit) reduce external wiring and box size.

  • Smart Commissioning: RJ45 interface for easy keypad connection, allowing parameter setting from anywhere in the machine room.

  • Standardized Interfaces: Rich encoder (Sin/Cos, UVW, ABZ) and communication options for global elevator control systems.





Basic Specifications
Carrier frequency2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted
Input frequency resolutionDigital setting: 0.01Hz
Analog setting: maximum frequency × 0.1%
Output frequency accuracyDigital setting: maximum frequency × ±0.01%
Analog setting: maximum frequency × ±0.01%
Control methodOpen-loop vector control (SVC)/ closed-loop vector control (FVC)/ VF control
Starting torque0.5Hz/180%(SVC); 0Hz/200%(FVC)
Speed range1:100(SVC)/1:1000(FVC) /1:50 (V/F)
Steady speed accuracy±0.5%(SVC)  ±0.05%(FVC)
Overload capacity150% rated current for 60 seconds; 180% rated current for 1 second.
Motor tuningTuning with load; Tuning without load
Acceleration and deceleration curveLinear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations
Maintenance controlCan be specified by any number of speeds
Multi-speed operationRealize up to 8-speed operation
Automatic voltage regulator(AVR)When the grid voltage changes, it can automatically keep the output voltage constant
Display And Operation
LED displayCan display setting frequency, output frequency, output voltage, output current and other parameters.
Protective functionPower-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection  40 kinds of protection.
Key lock and function selectionRealize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse.
Personalization
Power-on peripheral equipment safety self-testIt can realize safety detection of peripheral equipment such as grounding, short circuit etc.
Power failure emergency OperationSimple and convenient implementation of emergency operation plan
Over-speed protectionBuilt-in elevator overspeed protection function; multiple action options
Judge speed deviationBuilt-in speed deviation detection function; discover potential hidden dangers of elevators in time.
Forced shift functionIt has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom.
Direct docking functionCombined with direct docking commands for crawl-free operation
Motor temperature detectionTimely judge the motor temperature to eliminate potential safety hazards
Start compensationThree starting torque compensation methods: analog, digital, no weighing
QUICK buttonUser-defined shortcut menu
Timing controlConvenient timing control function
Input And Output Characteristics
Run command channelTwo channels: operation panel given, control terminal given.
Frequency source4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference.
Input terminal10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode.
2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input.
Output terminal3 digital output terminals
2 relay output terminals
1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency
Environmental Characteristics
Working temperature-10~+40℃, up to 50℃, air temperature change is less than 0.5℃/min
Storage temperature-40~+70℃
Application occasionIndoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc.
AltitudeLess than 1000 meters, derating is required for more than 1000 meters
HumidityLess than 95%RH, no condensation
Vibration resistance3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3)
Protection degreeIP20
Pollution levelClass 2 (dry, non-conductive dust pollution)


Customization & ODM Capabilities

More Than a Standard Product. It's Your Custom Starting Point
This platform is designed for adaptation and supports:
Software Tailoring
Modify parameters and develop specialized functions.
Hardware Adaptation
Adjust mechanical design and swap key components.
Complete Branding
Apply your logo and packaging seamlessly.

Related Article

content is empty!

Contact Us
Build Your Brand. 
Shape the Future of Industry.
Janson Controls Technologies(Shenzhen)Co.,Limited
 Add: 3rd Floor, Building E, Fuxing Industrial Park,No.110, Zhangqi Road, Guixiang Community, Guanlan Street, Longhua District, Shenzhen, China.
 Tel: +86-0755-29611160
Wechat: jansoncontrols
 Whatsup:+8613590499063
 Email: info@jansoncontrols.com

Quick Links

Service Support

Product Category

Copyright © 2026 Janson Controls Technologies (Shenzhen) Co., Ltd. Sitemap