Availability: | |
---|---|
Quantity: | |
FC90
JANSON CONTROLS
Various control modes: Support V/F control, with 3-point V/F curve setting and V/F separation control functions. Support keyboard, terminal, communication control, flexible frequency setting.
Rich in functions: supports multi-speed control, equipped with DC braking function to ensure fast shutdown. Provides textile variable frequency swing function, simple PLC program, two sets of motor parameter settings to meet automation needs.
International certification: CE certified, in compliance with international standards, ensuring product reliability and safety.
Multiple protection functions and control interfaces: With multiple fault protection functions and LED display, it provides 5 DI, 1 DO, 1 AI, 1 AO, 1 relay control, and rich interfaces.
Intelligent regulation and protection: Built in PID regulation module, support Modbus RS485 communication, realize remote control. With automatic torque boost and automatic slip compensation functions, it ensures strong torque at low frequency and will not trip even if the load is suddenly added.
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | GW (kg) |
3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | ||||||||||
FC90-2S-0.4G | 0.4 | 7 | 2.8 | 1.1 | 68 | 164 | 111 | 53 | 151 | 1 |
FC90-2S-0.75G | 0.75 | 13 | 5 | 2 | ||||||
FC90-2S-1.5G | 1.5 | 20 | 8 | 3 | ||||||
FC90-2S-2.2G | 2.2 | 24 | 11 | 4.3 | 89 | 217 | 146 | 64 | 206 | 2.5 |
3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | ||||||||||
FC90-4T-0.75G | 0.75 | 3.5 | 2.5 | 1.8 | 68 | 164 | 111 | 53 | 151 | 1 |
FC90-4T-1.5G | 1.5 | 5.8 | 4.2 | 3.0 | ||||||
FC90-4T-2.2G | 2.2 | 8.2 | 5.8 | 3.7 | ||||||
FC90-4T-4.0G | 4 | 13 | 9.5 | 6.5 | 89 | 217 | 146 | 64 | 206 | 2.5 |
FC90-4T-5.5G | 5.5 | 14.6 | 13 | 8.5 |
Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V, Three Phase 380~440V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage |
Output Frequency | V/F Control:0~300Hz |
Performance | |
Overload Capacity | 150% rated output current for 1 minute, 180% rated output current for 2 seconds |
Control Method | V/F control |
Run Command Setting Method | Operation Panel Setting, External Terminal Setting,Communication Setting. |
Speed Setting Method | Digital setting, analog setting, communication setting. |
Speed Setting Resolution | Digital setting: 0.01Hz,Analog setting: 1% × maximum frequency. |
Special Feature | |
Programmable Input & Output Terminals | Input& Output terminal function can be edited |
Process PID Adjustment Function | Built-in process PID module |
Simple PLC Function | Built-in simple PLC module, which can realize timing and multi-segment frequency output. |
Textile Wobble Function | Built-in textile swing frequency function module |
Motor group parameters | Two sets of motor parameters (motor parameter 1 and motor parameter 2), switch between them at will |
Protective Function | |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Overvoltage & Overflow Stall Control | Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping |
Output Short-to-Ground Protection | Effective protection function for output short circuit to ground |
Output Phase-to-Phase Short Circuit Protection | Output interphase short circuit effective protection function |
Input & Output | |
External analog power supply | +10V,load capacity 100mA |
Analog Input | AI1:Voltage 0~10V/0-20mA |
Analog Output | AO:0~10V / 0~20mA(Voltage/current selectable) |
Digital Input | DI1~DI5(DI5 can be selected as a high-speed pulse signal) |
Digital Output | DO |
Relay output | TA/TB/TC:Contact rating 250VAC/3A or 30VDC/1A |
MODBUS Communication | A+、B- |
Operation Display | |
LED Display | 5-digit LED digital Set frequency, output frequency, output voltage, output current, motor speed, output torque, digital terminals, status parameters, programming menu parameters and fault codes etc. |
Indicator Light | 3 units indicators, 3 status indicators |
Environmental Characteristics | |
Working Temperature | -10~+40℃, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50℃ Derating is required, output current derating 2% for each 1℃ |
Storage Environment Temperature | -40~+70℃ |
Application | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2~9Hz, 10m/s² at 9~200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |