1. The input and output terminal functions can be edited
2. Built-in process PLD module
3. Built-in simple PLC module, which can realize timing and multi-segment frequency output.
4. Built-in textile swing frequency function module, two sets of motor parameters (motor parameters
number and motor parameter 2), which can be switched between them
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | Diameter (mm) | GW (kg) |
3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||||
FC90-4T-0.75G | 0.75 | 3.40 | 2.10 | 1.50 | 68.00 | 164.00 | 111.00 | 53.00 | 151.00 | Ø4 | 1.00 |
FC90-4T-1.5G | 1.5 | 5.00 | 3.80 | 3.00 | 68.00 | 164.00 | 111.00 | 53.00 | 151.00 | Ø4 | 1.00 |
FC90-4T-2.2G | 2.2 | 5.80 | 5.10 | 4.00 | 68.00 | 164.00 | 111.00 | 53.00 | 151.00 | Ø4 | 1.00 |
Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V, Three Phase 380~440V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage |
Output Frequency | V/F Control:0~300Hz |
Performance | |
Overload Capacity | 150% rated output current for 1 minute, 180% rated output current for 2 seconds |
Control Method | V/F control |
Run Command Setting Method | Operation Panel Setting, External Terminal Setting,Communication Setting. |
Speed Setting Method | Digital setting, analog setting, communication setting. |
Speed Setting Resolution | Digital setting: 0.01Hz,Analog setting: 1% × maximum frequency |
Special Feature | |
Programmable Input & Output Terminals | Input& Output terminal function can be edited |
Process PID Adjustment Function | Built-in process PID module |
Simple PLC Function | Built-in simple PLC module, which can realize timing and multi-segment frequency output |
Textile Wobble Function | Built-in textile swing frequency function module |
Motor group parameters | Two sets of motor parameters (motor parameter 1 and motor parameter 2), switch between them at will |
Protective function | |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Overvoltage & Overflow Stall Control | Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping |
Output Short-to-Ground Protection | Effective protection function for output short circuit to ground |
Output Phase-to-Phase Short Circuit Protection | Output interphase short circuit effective protection function |
Input & Output | |
External analog power supply | +10V,load capacity 100mA |
Analog Input | AI1:Voltage 0~10V/0-20mA |
Analog Output | AO:0~10V / 0~20mA(Voltage/current selectable) |
Digital Input | DI1~DI5(DI5 can be selected as a high-speed pulse signal) |
Digital Output | DO |
Relay output | TA/TB/TC:Contact rating 250VAC/3A or 30VDC/1A |
MODBUS Communication | A+、B- |
Operation Display | |
LED Display | 5-digit LED digital Set frequency, output frequency, output voltage, output current, motor speed, output torque, digital terminals, status parameters, programming menu parameters and fault codes etc. |
Indicator Light | 3 units indicators, 3 status indicators |
Environmental characteristics | |
Working Temperature | -10~+40℃, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50℃ Derating is required, output current derating 2% for each 1℃ |
Storage Environment Temperature | -40~+70℃ |
Application | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2~9Hz, 10m/s² at 9~200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |